Insights · Duct Fittings

Marine HVAC Duct Penetrations and Cabin Units: What Shipyards and Outfitters Specify

How the fire rules shape a duct penetration, what sleeves, materials and cabin units a yard specifies, which documents it asks for, and what to put on the take-off so a ship set arrives right the first time.

Who this guide is for

This guide is for shipyards, offshore outfitters and marine HVAC contractors who buy duct components for accommodation and service spaces: sleeves that go through bulkheads and decks, the spiral duct either side of them, and the cabin units at the end of the run. On a ship these parts are where the HVAC drawing meets the fire plan, which is why they are ordered with more paperwork than the same parts ashore. The range we supply is on the marine duct penetrations page and the cabin air units page. This guide covers what the rules say, what a yard usually wants to see, and what to put on the take-off so the quote matches the job.

Why a penetration is not just a hole with a sleeve

Machinery and accommodation on a ship are divided into fire compartments by steel and insulated divisions, called A-class and B-class divisions, each with an insulation rating such as A-0, A-30, A-60 or B-15. SOLAS chapter II-2, regulation 9, sets out to contain a fire in the space where it starts. In the words of an IACS paper submitted to the IMO, it requires that penetrations of structural divisions by cables, pipes, trunks and ducts keep the fire integrity of the division. A duct that crosses a division is therefore part of the fire protection, not just part of the ventilation.

Three points from the regulation text matter to a buyer.

  • Penetrations of A-class divisions are tested. Regulation 9.3.1 says penetrations of A-class divisions are tested under the Fire Test Procedures Code, and for ventilation ducts it points to paragraphs 7.1.2 and 7.3.1 of the same regulation. The well-known exemption in 9.3.1, steel at least 3 mm thick and at least 900 mm long with no openings, is written for pipe penetrations. Do not carry that figure over to a duct sleeve without checking the duct paragraphs with your class surveyor.
  • Larger ducts need an automatic fire damper. Regulation 9.7.3.1.3, as amended by resolution MSC.365(93), requires automatic fire dampers in all ducts with a free cross-sectional area exceeding 0.075 m² that pass through A-class divisions. The damper is fitted close to the division, and the duct between the damper and the division is steel. The damper must close automatically, must also be closable by hand from both sides of the division, and must show its position with a visible indicator. For scale, a round duct of Ø300 has a free area of about 0.071 m² and Ø315 about 0.078 m², so the threshold falls between those two standard sizes. That is our own arithmetic on the internal diameter, so confirm it against the drawing.
  • You cannot split your way round the rule. The same paragraph says a duct over 0.075 m² must not be divided into smaller ducts at the penetration and joined up again on the far side to avoid fitting the damper. It also says a damper is not required where a duct passes through a space enclosed by A-class divisions without serving it, provided the duct has the same fire integrity as the divisions it penetrates.

Sleeve length and insulation extent have been a source of questions. In a paper put to the IMO in 2020, IACS proposed that the required sleeve length be measured along the centreline of the duct, which matters where a duct bends just below a deck, and that the insulation on a duct or sleeve extend at least 450 mm on the side of the division carrying the A-class insulation. For B-class divisions the same paper proposed that no clearance be left between the duct and the division. That paper is a draft interpretation, so ask your class society what it applies on your project. The damper itself is a separate product with its own test and approval, covered for buildings in our guide on fire and smoke damper integration. On a ship the idea is the same, but the tests and certificates are the marine ones.

What the penetration range covers

On our product page, penetration sleeves are made from Q235B steel and hot-dip galvanised, with mounting holes at both ends to fix the duct: three Ø4.2 holes up to Ø161 and four above. Sizes start at Ø80 and the sleeve length is to order. The range is:

  • Straight sleeves for flat bulkheads.
  • L profile sleeves where the duct has to turn through the penetration because space is tight. Leg lengths are made to order, so write the length of each leg on the schedule.
  • Insulated versions of both, with rock wool 15 mm thick at 60 kg/m³, for fire and condensation zones.
  • Penetration transitions and long penetration transitions that step the duct size at the sleeve, and male penetration joints that connect the sleeve to the next fitting.
  • Insulated spiral duct connectors for joining to insulated flexible hose.

The sleeve is welded into the steel, and the welding follows your yard's procedure. Decide early who restores the coating around the weld, and write it into the order. We do not state a fire class or class approval for these parts on the product page, so we do not claim one in this guide. What we can do is take the division class and sleeve length from your schedule and confirm at quotation what can be quoted and which documents come with it.

Materials, wall thickness and coatings

Galvanised steel

Galvanised is the working material for most accommodation ventilation. The sleeves are hot-dip galvanised Q235B. Our spiral duct is galvanised with a Z275 coating as standard, in standard sizes from Ø80 to Ø500 and lengths of 3, 4 or 5 m, with Z80 available to your specification. For sheet thickness the catalogue table runs from 0.5 mm for Ø80 to Ø315, through 0.6 mm for Ø350 to Ø450, to 0.8 mm at Ø500. Where your specification calls for something heavier, or names a standard, put it on the line and we quote to it. Sleeve gauges and seals are confirmed per line, so do not assume the spiral duct figures apply to the sleeve. The sheet metal gauge and thickness chart converts between gauge numbers and millimetres.

Stainless for wet and exposed areas

Duct in wet or exposed areas, such as galleys, laundries and anything that sees salt spray, is where stainless is usually considered. The cabin unit casing is offered in stainless steel, welded stainless dampers are in the damper range, and stainless spiral duct is available on request. A stainless sleeve is not listed on the penetration page, so if you need one, ask at the take-off stage and we confirm what is possible. Which grade to ask for is covered in our guide on 316L vs 304 stainless duct: in short, 304 is the default for indoor wet air, 316 is for chlorides, and the low-carbon L grades are for duct that is welded along its length. Write the grade on the schedule, not just the word stainless.

Insulation

Two routes exist. The insulated sleeves carry rock wool, and for runs of duct we also supply pre-insulated double-wall duct and fittings, which have glass wool between the inner and outer pipe. Insulation thickness is confirmed per item at quotation. Where a division carries an A-class rating, the fire insulation on the duct or sleeve has to satisfy the yard and the class society, so give us the class and the extension length your drawings call for rather than assuming a general figure.

Cabin air units

A cabin unit is the air terminal of the accommodation air conditioning: an attenuator box above the ceiling and a diffuser below it, designed for marine B-15 ceilings. It serves cabins, mess rooms, hospitals and meeting rooms. The listed data:

ItemData
Maximum air flow250 m³/h or 350 m³/h
Re-heatNone, 800 W or 1200 W electric, 230 V
CeilingMarine B-15, ceiling hole Ø155 to Ø160
CasingAluZinc steel, galvanised steel or stainless steel
LiningRock wool, sound and fire insulation
WeightAbout 6.2 kg (no heater) to 8.6 kg (1200 W)
ControlInlet damper for commissioning, knob in the diffuser, room thermostat on re-heat units

The inlet damper sets the air flow at commissioning and the knob in the diffuser lets the person in the room adjust it. Re-heat versions have a manual and an automatic over-heat switch. As a rule of thumb from the product page, 250 m³/h covers a typical single cabin and 350 m³/h suits larger rooms, but the room list with design air flow decides, not the rule of thumb. The design air flow itself comes from your heat load calculation. ISO 7547 is the standard that sets design conditions and calculation methods for air conditioning and ventilation of accommodation spaces on seagoing merchant ships, with annexes for machinery control rooms, the wheelhouse and dry provision stores. It tells the designer how much air each space needs, and the unit is then chosen to deliver it.

Offshore installations work from a different document. ISO 15138 covers heating, ventilation and air conditioning on offshore production installations, including design, testing, installation and commissioning, and for installations subject to class or IMO and MODU rules it points the user to the HVAC requirements in those rules. If your project is offshore, check which regime the project specification names before you write the schedule. See also the silencers and attenuators page if your design needs sound attenuation outside the cabin units.

What shipyards usually ask for

Every yard has its own list, and the project specification and the class society win over any general guide. The requests usually fall into five groups.

  • Class and flag. The class society and the flag administration, because they decide which approvals are acceptable.
  • Fire division data. The class of each division crossed (A-0, A-30, A-60, B-15 and so on), sleeve length, and how far the insulation must extend.
  • Test evidence for the arrangement. Penetrations of A-class divisions and fire dampers are tested under the 2010 FTP Code, adopted by resolution MSC.307(88). Part 3 of its Annex 1 covers tests for A, B and F class divisions, and Appendix 2 of that part covers windows, fire dampers, pipe penetrations and cable transits. Where a damper is supplied, a yard will usually ask for a type-approval or type-examination certificate that refers to SOLAS II-2/9 and the FTP Code. Ask your class society which approval scheme applies to your flag, for example the EU Marine Equipment Directive for EU-flagged ships. For plain galvanised sleeves and spiral duct, ask your surveyor whether a material certificate is enough.
  • Material documents. Mill or material certificates, coating details, and the grade for any stainless.
  • Drawings and marking. Dimensions per penetration, and the marking or tagging scheme so each part is found at the right frame.

We do not publish a certificate list on the product pages. Tell us which documents your yard needs when you send the take-off, and we confirm at quotation what can be supplied, so there are no surprises at the receiving inspection.

What to send us to quote

Send one row per penetration or unit. The table shows the columns we need.

ItemSizeQuantityMaterial and coatingNotes
Straight penetration sleeveDuct Ø, sleeve lengthper orderHot-dip galvanised, gauge or standardBulkhead or deck, division class
Insulated L profile sleeveDuct Ø, leg lengths L1 to L4per orderHot-dip galvanised, rock wool 15 mmWhich side carries the division insulation
Penetration transitionBoth diameters, lengthper orderAs the sleeveStraight or long transition
Spiral ductØ80 to Ø500 or largermetres, per orderZ275 or Z80, or stainless gradeLength per piece, seal type
Cabin unit250 or 350 m³/hper orderAluZinc, galvanised or stainless casingRe-heat none, 800 W or 1200 W; thermostat

Add the class society and flag, the documents the yard requires, the delivery port, and whether the goods ship alone or with a machine order. Quantity is quoted per order, and if the ship is one of a series, say how many hulls so we can plan the packing. Spiral pipe is mostly air, so the packing plan, with smaller sizes nested inside larger ones where diameters allow, affects freight. There is no price list, because the price depends on diameter, gauge, coating, insulation and quantity on each line. For help writing the list, see the bulk buying take-off checklist.

Common mistakes

  • Writing "sleeve, 200" with no sleeve length, bulkhead or deck, or division class.
  • Assuming the pipe-penetration figure of 3 mm and 900 mm applies to ducts.
  • Forgetting that a duct above 0.075 m² through an A-class division needs a fire damper, and that it cannot be split to avoid one.
  • Ordering stainless without the grade, or galvanised for a duct that will see salt spray.
  • Selecting cabin units by cabin count instead of the design air flow per room.
  • Leaving the document list until the goods arrive at the yard.

Send your penetration and cabin unit list for a quote →

Taokron supplies these penetrations and cabin units. Catalogue figures are confirmed on the quotation for your order.

FAQ

What do I send to get marine duct penetrations and cabin units quoted?

Your take-off or the drawing schedule as a list, Excel, PDF or a photo. For each penetration give the duct diameter, sleeve length, bulkhead or deck type, the fire class of the division and whether the sleeve is insulated. For cabin units give the room list with design air flow, ceiling type, whether re-heat is needed and the casing material. Add the delivery port and whether the goods ship alone or with a machine order.

Do your penetration sleeves carry a class approval?

The product page lists the material, insulation, mounting holes and sizes, and it does not state a class approval, so we do not claim one here. If your yard or class society needs a certificate or test report for the penetration arrangement, tell us at the take-off stage and we confirm at quotation which documents can be supplied.

Which SOLAS rule decides whether a duct needs a fire damper at an A-class division?

SOLAS regulation II-2/9.7.3.1.3, as amended by resolution MSC.365(93), requires automatic fire dampers in ducts with a free cross-sectional area exceeding 0.075 m² that pass through A-class divisions, with an exception for ducts that pass through spaces enclosed by A-class divisions without serving them. Your class society and flag administration decide how it applies to your ship, so treat this guide as a pointer to the text, not a substitute for it.

What materials are the sleeves and cabin units made from?

Penetration sleeves are Q235B steel, hot-dip galvanised, with rock wool 15 mm (60 kg/m³) on the insulated versions. Cabin unit casings are AluZinc steel, galvanised steel or stainless steel, lined with rock wool. Stainless spiral duct is available on request. Gauges and coatings are confirmed per line on the quotation.

What air flows and heater sizes do the cabin units cover?

Two sizes: 250 m³/h and 350 m³/h maximum air flow. Re-heat versions carry an 800 W or 1200 W electric heater at 230 V, controlled by a room thermostat, with a manual and an automatic over-heat switch. They are designed for marine B-15 ceilings with a ceiling hole of Ø155 to Ø160.

Can you supply the whole accommodation duct system on one take-off?

Yes. Spiral duct and fittings, insulated duct, penetrations, clamps, flexible hose, air valves and cabin units can go on one take-off, and the goods can ship alone or share a container with a machine order. There is no price list: each line is quoted from your take-off.

Duct Shop Notes

One email a month for duct shop owners

Notes on machine choices, shop layout, duct standards and new machines. Reply "unsubscribe" any time to stop.

Engineer reply

Send your take-off: items, sizes and quantities per order. Ryan Tao replies with a quotation and lead time.

Ask an engineer

Engineer reply

Send your take-off

Tell us the items, sizes and quantities you need. Ryan Tao replies personally.

Guide: Marine HVAC Duct Penetrations and Cabin Units: What Shipyards and Outfitters Specify